info@hmgindia.com
Call Us :- 08045804755
Ceiling Suspended OT Laminar

Ceiling Suspended OT Laminar

150000 INR/Piece

Product Details:

  • Installation Type Ceiling Suspended
  • Material Stainless Steel 304
  • Dust HEPA Filtered air (0.3 micron)
  • Connectivity Type Wired
  • Equipment Type Ceiling Suspended OT Laminar Air Flow Unit
  • Output Laminar Air Flow
  • Efficiency (%) >99.97%
  • Click to view more
X

Ceiling Suspended OT Laminar Price And Quantity

  • 150000 INR/Piece
  • 1 Piece
  • Integrated LED Lighting option
  • Food grade neoprene rubber
  • ISO Class 5 (as per ISO 14644-1)
  • Flame retardant structure
  • 0.45 ± 0.05 m/s at grill level
  • Hermetically sealed, leak-proof design
  • Perforated SS for uniform air distribution
  • Minimum 5 years under normal conditions
  • Double skinned with insulation

Ceiling Suspended OT Laminar Product Specifications

  • Fully Automatic
  • 0.75 HP to 2 HP
  • Integrated Plenum with Diffusers
  • HEPA 99.97%, Pre-filter 95%
  • 50 Hz
  • Low; Energy Efficient Motors
  • Approx. 150-200 kg
  • 15 25 mm WG
  • <65%
  • HEPA & Pre Filters
  • Operation Theatre, Modular OT
  • Matte White Coated or Silver
  • Low vibration, corrosion resistance, quiet operation, smooth finish
  • Below 65 dB(A)
  • Digital with Remote/Touch Panel
  • Custom as per fitting requirements
  • 15003500 m/hr
  • >99.97%
  • Low maintenance, easy service access
  • 230V AC, 50 Hz
  • >99.97% removal for 0.3 micron particles
  • Wired
  • 2400 mm x 2400 mm x 750 mm (Standard, Customizable)
  • Ceiling Suspended OT Laminar Air Flow Unit
  • Laminar Air Flow
  • Stainless Steel 304
  • HEPA Filtered air (0.3 micron)
  • Custom as per OT size
  • Ceiling Suspended
  • Integrated LED Lighting option
  • Food grade neoprene rubber
  • ISO Class 5 (as per ISO 14644-1)
  • Flame retardant structure
  • 0.45 ± 0.05 m/s at grill level
  • Hermetically sealed, leak-proof design
  • Perforated SS for uniform air distribution
  • Minimum 5 years under normal conditions
  • Double skinned with insulation

Ceiling Suspended OT Laminar Trade Information

  • 1 Piece Per Day
  • 1 Week
  • Western Europe, Australia, North America, Eastern Europe, Africa, Central America, Middle East, South America, Asia

Product Description

Having core competency in the domain, we are betrothed in providing the finest quality collection of Ceiling Suspended OT Laminar. Widely demanded in hospitals and nursing homes, this is fitted in operation theater for removing a number of infective organisms present in the air. The offered product is manufactured by utilizing top grade components and sophisticated techniques under our experts' observation. Moreover, our precious patrons can avail this Ceiling Suspended OT Laminar from us at economical rates.

Key Points:

  • Easy to install
  • High performance
  • Requires less maintenance
  • Hassle free functioning


Optimized Air Quality for Sterile Environments

Our Ceiling Suspended OT Laminar Unit maintains ISO Class 5 air purity, essential for infection control in medical facilities. The advanced HEPA and pre-filter system ensures >99.97% removal of 0.3 micron particles, providing a safe environment and reducing risk during critical operations.


Innovative Construction for Reliability

With double-skinned plenum, hermetically sealed edges, and flame retardant SS304 body, this unit offers durability and safety. The food-grade neoprene rubber gasket prevents leaks and enhances the longevity of the filtration system, ensuring dependable, long-term operation.


Energy-Efficient and Easy Maintenance

Designed for low energy consumption, quiet operation below 65 dB(A), and easy service access, our laminar air flow unit minimizes operational costs and downtime. Integrated digital controls via remote or touch panel allow convenient monitoring and adjustment, promoting efficiency in OT settings.

FAQs of Ceiling Suspended OT Laminar:


Q: How does the ceiling suspended OT laminar air flow unit ensure uniform air distribution in operation theatres?

A: The unit utilizes perforated stainless steel diffusers to evenly distribute filtered air throughout the theatre, maintaining a constant laminar flow velocity of 0.45 0.05 m/s at grill level. This design helps maximize sterility and ensures contaminant-free air reaches the surgical area.

Q: What filtration systems are used, and what is their efficiency?

A: The unit incorporates HEPA filters with >99.97% efficiency for 0.3 micron particles as well as 95% efficient pre-filters. This dual filtration system delivers ultra-clean, ISO Class 5 air in operation theatres, crucial for reducing surgical site infection risk.

Q: Where is this equipment typically installed and what are its application areas?

A: It is designed for ceiling suspended installation, making it ideal for modular operation theatres, critical care areas, and other sterile facilities. Customizable dimensions and capacities ensure compatibility with various OT sizes and layouts.

Q: What controls and features enhance user convenience?

A: A digital control system with remote or touch panel interface allows easy adjustment of unit settings. Integrated LED lighting and a quiet, low vibration motor enhance operator comfort and maintain a conducive surgical environment.

Q: What maintenance processes are recommended for optimal usage life?

A: Routine inspection and replacement of HEPA and pre-filters, along with periodic cleaning of the diffusers and plenum, are advised. The design provides easy service access, and low maintenance requirements support a minimum usage life of five years under normal conditions.

Q: How does the unit support energy efficiency and low operational costs?

A: Equipped with energy-efficient motors and low power consumption (0.75 HP to 2 HP), the unit helps reduce electricity costs. Its durable stainless steel construction further minimizes the need for frequent replacements or repairs.